High Voltage:10KV 35KV
Low Voltage:400V 6.3KV
Rated Capacity:500kVA 800kVA 1000kVA 1250kVA 1600kVA
Connection Vector Group:YNd11,Dyn11
Cooling Method:ONAN(Oil Natural Air Natural)/AN(Air Natural)
Protection Level:IP44 IP54 IP65
Short-Circuit Withstand Capacity:10kA 15kA 20kA
Category
Compact Substation
Share to
Send Inquiry
Description
Technical Parameters

Streamlined Structure & Expansion Flexibility

 

  • The 10kV Compact Box Type Substation launched by Kechang Electric adopts the State Grid standard streamlined design, removes redundant switch components, and controls the size of the box at 2.65m in length ×1.35m in width×2.1m in height.
  • At the same time, a standardized expansion interface is reserved. The low-voltage outlet can be expanded from 4 channels to 6 channels, and the compensation capacity can be flexibly adjusted according to the rated capacity of the transformer. 10%-15%, without the need to replace the box as a whole, it perfectly solves the contradiction between "limited space" and "late expansion", and adapts to scenarios where the load is gradually increasing.

 

Anti-Condensation & Ventilation Optimization

 

Condensation problems in underground garages and humid low-lying sites can easily lead to equipment insulation failures. Buyers attach importance to the ability to actively prevent condensation.The product is equipped with an intelligent anti-condensation system, which automatically regulates the humidity in the box ≤60% through the linkage of a low-power heater and a directional ventilation tank through a temperature and humidity sensor to avoid moisture condensation.The ventilation trough adopts a "top row and bottom inlet" design, and is equipped with a dust-proof filter to not only ensure the efficiency of natural air cooling, but also block dust intrusion. The protection level is IP54, and it can operate stably at -25℃~45℃ and 95% relative humidity without manual intervention to dehumidify.

 

High quality Compact Box Type Substation

 

Arc Flash Protection & Safety Enhancement

 

Arc failure inside the box transformer can easily cause equipment damage and casualties, and buyers have an urgent need for precise protection.The product has a built-in arc flash detection sensor with a response time of ≤2ms. It can quickly capture the arc optical signal and activate the fast tripping module to limit the arc combustion time. At the same time, the box body reserves a pressure relief channel to quickly release the internal pressure and avoid the box body exploding.The internal insulating parts are cast with F1-grade flame-retardant epoxy resin and have passed the IEC 60298 anti-arc light test, which greatly improves operating safety and adapts to the surrounding power distribution scene in densely populated areas.

 

 

Low occupied Compact Box Type Substation

 

Precision Compensation & Voltage Stability

 

Buyers attach importance to the voltage stability of the power distribution system to avoid terminal equipment failure due to load fluctuations.

The product is equipped with a modular reactive power compensation module, the compensation capacity can be accurately matched according to the rated capacity of the transformer, and supports phase separation compensation, which can effectively suppress three-phase imbalance and voltage fluctuations, and stabilize the power factor above 0.95.

At the same time, the impedance design of the transformer is optimized, and the impedance voltage deviation is controlled within ±5% to ensure that the voltage regulation rate is ≤±2% when the load is switched, which is suitable for commercial and industrial scenarios where precision equipment is concentrated.

 

Standard Compliance & Custom Support

 

Project acceptance and personalized adaptation are the core concerns of buyers.

Kechang Electric strictly follows the 2020 version of the State Grid standardized design plan and IEC 60076 standard production, and has passed CE and RoHS certification. Each equipment comes with a complete factory withstand voltage and local discharge test report, which can be directly adapted to the State Grid supporting project acceptance.

 

Product Specifications

 

Project Unit Parameter
High
pressure
side
Rated frequency Hz 50
Rated voltage KV 6/10/35
Maximum operating voltage KV 6.9/11.5/40.5
Rated current A 400/630/1250
Transfer current A 1200-3150
Rated short-circuit switch current (current-limiting fuse) KA 25-50
Transformer Rated voltage KV 50
Rated capacity KVA 30-2000
Tap range % ±2*2.5/±5%
Connection group   Yyn0/Dyn11
Impedance voltage % 4.4/5.6/8
Low
pressure
side
Rated voltage V 220/380/690/800
Main circuit rated current A 50-4000
Branch current A 5-800
case Protection level IP23/IP33/IP65
Noise level(dB) ≤50