What are Power Transformers

 

A power transformer is a large-scale static electromagnetic equipment specially designed for high-voltage power transmission and backbone grid systems. It relies on the principle of electromagnetic induction to step up or step down high-voltage alternating current, minimizing energy loss during long-distance bulk power transportation.
Installed in central power plants, regional substations and large grid hubs, it serves as the core equipment of the entire power transmission network to realize efficient, stable and safe electric energy delivery across long distances.

Core Advantages of Our Power Transformers

Energy Saving & Low Loss

Ultra-low no-load and load loss, compliant with international high-efficiency energy-saving standards, effectively reducing grid operation costs.

 

Reliable Internal Structure

Adopts high-purity copper coils and high-permeability silicon steel sheets, stable operation with strong overload resistance and anti-short-circuit capability.

 

Flexible Customization Support

Fully customizable: adjustable rated capacity, voltage ratio, impedance, tap changer mode and cooling method per client’s national grid standards.

 
 
First 12 Last
 
Product Specifications

 

 

Model Number

Rated Volume Quantity
(KVA)

Voltage Combination(KV)

Connection Group Label

No-load Loss

(W)

Load Loss

(W)

No-load Electricity

(%)

Short Circuit Resistance

(%)

High
Voltage

High Voltage Tap Range

Low Voltage

S13-630

630

35

±5%

or

±2×2.5%

3.15

6.3

10.5

yd11

580

7860

0.65

6.5

S13-800

800

690

9400

0.65

6.5

S13-1000

1000

810

11500

0.65

6.5

S13-1250

1250

980

13900

0.55

6.5

S13-1600

1600

1180

16600

0.45

6.5

S13-2000

2000

1520

18300

0.45

5.5

S13-2500

2500

1790

19600

0.45

6.5

S13-3150

3150

35

38.5

±5%
or
±2×2.5%

3.15
6.3
10.5

2130

23000

0.45

7

S13-4000

4000

2530

27300

0.45

7

S13-5000

5000

3020

31300

0.45

7

S13-6300

6300

3670

35000

0.45

8

S13-8000

8000

35

38.5

±5%

or

±2×2.5%

3.15
3.3
6.3
6.6
10.5

ynd11

5040

38400

0.35

8

S13-10000

10000

6090

45300

0.35

8

S13-12500

12500

7000

53800

0.30

8

S13-16000

16000

8470

65800

0.30

8

S13-20000

20000

10080

79500

0.30

8

S13-25000

25000

11900

94000

0.25

10

S13-31500

31500

14140

112000

0.25

10

 

Key Characteristics of a Power Transformer

 

Voltage Range

Typically 66 kV – 750 kV

Power Rating

5 MVA to 1200+ MVA

Installation Location

Found in generation stations, transmission substations, and grid tie points

Cooling System

Oil-based (ONAN, ONAF, OFAF), sometimes with forced-air or water

Core Function

Uses electromagnetic induction between coils to change AC voltage

 

Different Types of Power Transformers

Power transformers can come in many forms, often operating in different ways and serving different types of electrical energy needs. Here are some of the many different types of power transformers that can be found in substations:

Three Phase 2 Winding OLTC Power Transformer
110kV Oil-immersed Power Transformers
Large Power Transformers
Three Phase 2 Winding OLTC Power Transformer

Liquid-Filled Power Transformers: Liquid-filled transformers are what Power Transformer specializes in, and these are the most straightforward type. These transformers convert power from transmission to a more manageable distribution voltage like many others, but they’re unique due to their oil-based cooling method. Liquid is contained within a central drum that circulates throughout the transformer, efficiently cooling its components. This cooling method allows for a higher power yield and greater efficiency. Any transformer that converts power from a high voltage to a lower one is considered a “step-down” transformer.


Step-Up Transformers: For some industrial applications, sometimes the voltage of a current isn’t high enough. Contrary to the step-down transformers usually found in substations, step-up transformers actually raise the voltage of a current to a higher value.


Rectifier Duty Transformers: For industries that require large amounts of direct current (DC) energy, rectifier transformers convert alternating current (AC) power into direct current, a process known as rectification. Rectifier duty transformers can be used to power electronics like computers, radios, and televisions, which require a constant supply of DC. They are also used in industries that involve welding, since rectifier duty transformers deliver the highly polarized voltage of power that welders need.


Grounding Transformers: If electrical energy is coming from an ungrounded source, such as in Delta or Wye connection systems, this can pose a significant fire hazard, and be dangerous to use. Grounding transformers convert electrical energy from ungrounded to a grounded state, transferring energy safely. This is similar to what three-prong grounded electrical outlets do, whereas ungrounded two-prong outlets can lead to a higher likelihood of electrical fires.

 

The Power Transformer Working Principle

 
 

An alternating current is passed through the primary winding. It establishes a changing magnetic field around the transformer’s iron core. This occurs due to the magnetic effect of current flow.

 
 

As the alternating voltage cycles, the magnetic field strength inside the core correspondingly expands during one half of the cycle and collapses back during the other half.

 
 

This continuously varying magnetic flux permeates from the inner core and cuts through the secondary winding wrapped around the same iron core structure.

 
 

According to Faraday’s law of electromagnetic induction, the changing magnetic field produces an electromotive force (EMF) in the secondary winding coils as the flux cuts through it.

 
 

The magnitude of induced EMF in the secondary depends upon factors like the rate of change of flux, number of turns in the winding, and other transformer specifications.

 
 

By adjusting the number of turns in the two windings, the induced voltage in the secondary can be stepped up or down relative to the primary voltage using the transformer’s turn ratio.

 
 

This transformed voltage is then available for onward power transmission or distribution applications after passing through the isolated secondary winding.

 

 

Common Voltage Range of Power Transformers

Power transformers cover a wide range of voltage classes, selected according to unit capacity and field‑application requirements. Voltages from 110 kV up to 750 kV are widely used for bulk power transmission, with typical applications shown below:

110kV Power Transformers

Used for regional power distribution. It steps down high‑voltage power to supply industrial and commercial end‑users.

01

220kV Power Transformers

Suited for long‑distance power transmission. Connect power plants and substations to cut down transmission energy losses.

02

420kV Power Transformers

Forms part of main power grid backbone, to transfer large‑volume power across different regions.

03

500kV Power Transformers

Built for ultra‑high‑voltage transmission lines. Inter‑connect major cities and provinces to keep power grid stable.

04

750kV Power Transformers

Applied in large‑capacity, long‑haul transmission lines. Supports cross‑country or inter‑continental efficient power transfer.

 

05

 

Primary Locations Where Power Transformers Are Used

 

Location

Typical Voltage Range

Power Rating (MVA)

Function

Power Generation Plants

11–25 kV (input), 132–400 kV (output)

50–315+ MVA

Step-up voltage to transmission levels

High-Voltage Transmission Substations

132–765 kV

160–1000+ MVA

Interconnect grids, adjust voltage levels

Grid Interconnection Nodes

220/132/400 kV

250–630 MVA

Balance regional grid loads and flow directions

Receiving or Step-Down Substations

400 → 132 kV, 220 → 66/33 kV

63–250 MVA

Prepare power for distribution networks

Renewable Energy Collector Substations

33/66 → 132 kV (wind/solar)

10–100 MVA

Step up renewable output to grid level

Heavy Industrial Plants

33/11 kV (in), 132 kV (out)

10–200 MVA

Run large motors, furnaces, and equipment

 

Certificates

 

productcate-1-1
productcate-1-1
productcate-595-836
productcate-595-836

 

 

FAQ

 

Q: What is your delivery time ?

A: Depend on the type of transformer.

Q: What is your payment term?

A: 30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it.

Q: Are your transformers supported for customization?

A: Yes, of course. Please provide specific drawings or parameters, and we will provide a quotation for you after evaluation.

Q: Do you offer guarantee for the products?

A: Yes. Different transformers is different. We offer at least one year guarantee for all of our transformers.

Q: Do you accept Factory Acceptance Test?

A: Yes. It's available. And we are responsible for each set transformer's testing (ICE).

Q: Do you assign engineer for after-sale service?

A: Yes. For our products,we all provide after-sale installation instructions service

As one of the leading power transformers manufacturers and suppliers in China, we warmly welcome you to wholesale cheap power transformers from our factory. All customized products are with high quality and competitive price.

1 5 kva transformer, 2kw transformer, 225 kva transformer
Send Inquiry
Get Support for Your Power‑Distribution Projects

With our patented technologies, feel free to send your project-related inquiries via phone,
email or our online form. Our electrical-engineering specialists will reply to you promptly.

Submit Your Inquiry