Substation Switchgear

Substation Switchgear

Details
Rated Voltage:10kV 35kV 110kV
Rated Current:630A 1250A 2000A 3150A
Short-Circuit Breaking Capacity:25kA 31.5kA 40kA
Protection Level:IP44 IP54
Connection Scheme:Single busbar/Single busbar section
Core Switching Component:SF6 circuit breaker/Vacuum circuit breaker
Frequency:50Hz 60Hz
Category
Switchgear
 
Send Inquiry
Description
Technical Parameters

Products Description

 
10kV 630A switchgear

Reliable medium voltage switchgear for substations

 

Substation switchgear plays an important role in the power distribution system.It is used to connect, control, and protect the incoming and outgoing line loops, and allows the safe isolation of electrical equipment during inspection or maintenance. Our 35kV substation switchgear is designed for substations, industrial facilities, renewable energy projects and other medium voltage power distribution systems.Its configuration can be flexibly adjusted according to the project's voltage level, rated current, short-circuit tolerance requirements and protection scheme. 

Learn More>>

 

competitive advantage
 

Safe operation and protection

During normal operation, the switchgear needs to reliably perform circuit switching operations and provide protection in the event of a failure. The equipment can be configured with vacuum circuit breakers, protection relays, current transformers, voltage transformers, busbars and metering components according to customer needs. The mechanical and electrical interlocking function helps prevent misoperation. The independent internal compartment design optimizes the layout of the main circuit, busbar and control area, making inspection and maintenance more convenient.

Rugged metal-enclosed design

The metal-enclosed structure can not only protect the internal electrical components, but also effectively separate the different functional areas in the cabinet. Its layout can be customized for incoming, outgoing, transformer connection and female applications. The cabinet design fully considers the convenience of maintenance, and technicians can directly contact related components without unnecessary operations on other parts of the system.

Flexible configuration scheme

According to specific application scenarios, configuration options include:

1. Rated voltage and current

2. In and out line layout 3. Vacuum circuit breaker Busbar configuration

4. Protection and metering system

5. Cable inlet and connection method

6. Indoor installation requirements

7. On-site or remote control

This flexibility makes the switchgear suitable for both new substation projects and the upgrading of power distribution systems.

Adapt to stable operation in a variety of environments

Substation equipment often operates in environments affected by dust, humidity, temperature fluctuations and continuous electrical loads. The switchgear ensures the stability of operation through reasonable insulation distance, shell protection level and internal ventilation design. For projects in coastal areas, industrial parks, high-temperature areas or dusty environments, the appropriate cabinet protection level and component configuration can be selected according to on-site working conditions. Standards and quality control

 

Product Applications

1. Utility grid substations: used for inlet, outlet and feeder loops in medium voltage power grids.

2. Industrial power system: suitable for factories, mines, metallurgy, oil and gas facilities and other industrial projects.

3. Renewable energy projects: used for the collection and distribution of medium-voltage energy in solar and wind power plants.

4. Commercial buildings: suitable for large-scale buildings and public facilities that require reliable medium-voltage power distribution. 5. Transportation infrastructure: suitable for power distribution systems of railways, subways and airports.

6. Data center: Provide switching and protection functions for medium-voltage power systems that require continuous operation.

switchgear KYN28

 

Product Specifications

 

 

Project Unit Parameter
Rated voltage V AC400 AC690 DC750
Rated frequency HZ 50
Rate insulation voltage V AC1000 DC1500
Rated impact voltage resistance KV 8
Main bus Rated current A Up to 5000
Rated peak withstand current(1s) KA 105, 176, 220
Rated short time withstand current (1s) KA 50, 80, 100
Gounding system TT, IT, TN-S, TN-C-S
Protection level of cabinet IP30, IP40, IP54

Hot Tags: substation switchgear, China substation switchgear manufacturers, suppliers, factory, containerised switchgear, oil insulated switchgear, gas switchgear, 13.2 kv switchgear, flameproof switchgear, 33kv indoor switchgear

Send Inquiry
Get Support for Your Power‑Distribution Projects

With our patented technologies, feel free to send your project-related inquiries via phone,
email or our online form. Our electrical-engineering specialists will reply to you promptly.

Submit Your Inquiry