Embedded Poles Type VCB

Embedded Poles Type VCB

Details
Rated Voltage:10KV 24KV 35KV
Rated Current:630A 1250A 2000A 3150A
Rated Short-Circuit Breaking Capacity:25kA 31.5kA 40kA
Insulation Medium:Epoxy Resin Solid Insulation
Insulation Level:LI75kV/AC42kV LI125kV/AC50kV LI185kV/AC95kV
Protection Level:IP44 IP54
Mechanical Service Life:10000 20000 Operations
Category
Circuit Breaker
 
Send Inquiry
Description
Technical Parameters

Vacuum Circuit Breaker

 

Product Introduction

Kechang (Kechang) Fixed pole vacuum circuit breaker (VCB) is a medium voltage switchgear used in substations, industrial power systems and power distribution equipment. The product abandons the traditional design of the vacuum arc extinguishing chamber and the exposed conductive components, and casts and encapsulates the core components in an epoxy resin insulated pole column. This design not only gives the circuit breaker a simple and compact structure, but more importantly, it can effectively protect the insulation system from dust, moisture and other pollutants. The circuit breaker is mainly used to cut off the normal load current and cut off the fault current in the event of a short circuit.In addition, it can be installed in various types of medium voltage switchgear according to the customer's cabinet design requirements.

Learn More>>

 

Product Feature

1. APG epoxy resin fixed pole column

 

The fixed pole column is manufactured by APG (automatic pressure gel) process.During the molding process, the vacuum arc extinguishing chamber and related conductive components are completely coated with epoxy resin to form an integrated insulating unit. For equipment installed in environments that are difficult to completely avoid dust and humidity (such as factories or substations), this structure has significant practical advantages: fewer insulating surfaces need to be cleaned, and the possibility of condensation affecting the main insulation is greatly reduced. The selected epoxy resin material has excellent mechanical strength, heat resistance and long-term stability. The final product is a solid-state insulated vacuum circuit breaker, which does not need to rely on oil or SF6 gas for arc extinguishing.

fixed type vacuum circuit breaker
 

2. Compact structure

 

In the renovation projects of old substations, space is often a limiting factor.The embedded pole design helps to reduce the interphase distance, thereby maintaining the compactness of the circuit breaker assembly. This feature makes the arrangement of vacuum circuit breakers in the medium voltage switchgear more flexible and convenient, especially for occasions where the existing power distribution room cannot be expanded.According to the layout requirements of the switchgear, two versions are available: fixed type and hand-car type (retractable type). The circuit breaker body and operating mechanism have been assembled before leaving the factory. The on-site installation work mainly involves mechanical fixation, main circuit connection and control line wiring, without the need for complex circuit breaker body assembly.

withdrawable circuit breaker
 

3. Vacuum arc extinguishing and fault protection

 

The vacuum circuit breaker uses a vacuum arc extinguishing chamber for arc extinguishing.When a fault occurs, the contacts in the arc extinguishing chamber are separated, thereby quickly cutting off the current. Vacuum technology also avoids the use of insulating oil and SF6 gas during normal operation. For different power distribution systems, Kechang can provide configuration solutions with short-circuit switching currents up to 40kA. The rated current, operating mechanism and protection components can be selected according to the switchgear and system requirements.

IP44 vacuum circuit breaker
 

Less daily maintenance workload

 

There is no need to check or replace the insulating oil, and the vacuum arc extinguishing chamber is in a sealed state during normal operation. The solid-sealed insulation structure also reduces the number of exposed conductive and insulating parts. For users of substations or distribution systems with limited maintenance personnel, this simplifies daily inspections.In addition, according to needs, the circuit breaker can also be equipped with temperature monitoring and intelligent control functions.

10kV vacuum circuit breaker
 

 

Product Specifications

 

Number Parameter name Unit Technical Parameters
1 Rated voltage kV 12
2 Rated short-time frequency withstand voltage (1 min) kV 42
3 Rated lightning impulse withstand voltage (peak) kV 75
4 Rated frequency Hz 50
5 Rated current A 630/1250/1600/2000/2500/3150/4000
6 Rated short-circuit breaking current kA 20 25 31.5 40
7 Rated short-time withstand current kA 20 25 31.5 40
8 Rated short circuit duration S 4
9 Rated short-circuit closing current kA 50 63 80 100
10 Rated peak withstand current kA 50 63 80 100
11 Number of rated short-circuit current starts times 30 30 30 20
12 Rated individual capacitor bank opening current A ≤630
13 Rated back-to-back capacitor bank opening current A ≤400
14 Rated capacitor bank closing inrush current kA 12.5(frequency≤1000Hz)
15 Closing time ms ≤80
16 Split time ms Maximum Voltage ≤40
ms Rated Voltage ≤50
ms Minimum Voltage ≤60
17 Time of ignition ms ≤15
18 Mechanical life (M2) times 30000
19 Allowable cumulative thickness of dynamic and static contact wear mm 3
20 Rated closing operating voltage V AC/DC 220, AC/DC 110
21 Rated breaking operating voltage V AC/DC 220, AC/DC 110
22 Rated operating voltage of energy storage motor V AC/DC 220, AC/DC 110
23 Rated power of energy storage motor W 80 (40KA Motor speed 100W)
24 Energy storage time s ≤15
25 Contact opening distance mm 9±1
26 Over traveling distance mm 3.5±0.5
27 Contact closing bounce time ms ≤2
28 Three-phase switching and closing non-synchronous ms ≤2
29 Contact splitting rebound amplitude mm ≤3
30 Contact closing contact pressure kA 20 25 31.5 40
N±8% 2200 2500 3100 4750
31 Average breaking speed (contacts separated by 6mm) m/s 1.1±0.2
32 Average closing speed (6mm contact closure) m/s 0.6±0.2
33 Dominant electric circuit resistance A 630 1250 1600-2000 ≥2500
34 μΩ ≤50 ≤45 ≤35 ≤25
Rated operating sequence (1) 20~31.5KA   Minutes - 0.3s - combined minutes - 180s - combined minutes
35 Rated sequence of operation (2) 40KA   Minutes - 0.3s - combined minutes - 180s - combined minutes
Secondary circuit frequency withstand voltage (1min) V 2000

Hot Tags: embedded poles type vcb, China embedded poles type vcb manufacturers, suppliers, factory, outdoor circuit breaker, hv circuit breaker, dc circuit breaker, blown circuit breaker, standard circuit breaker, industrial circuit breaker

Send Inquiry
Get Support for Your Power‑Distribution Projects

With our patented technologies, feel free to send your project-related inquiries via phone,
email or our online form. Our electrical-engineering specialists will reply to you promptly.

Submit Your Inquiry