1. Product Introduction
10kV High Voltage Vacuum Circuit Breaker adopts a fully sealed permanent magnet operating mechanism, high‑altitude adapted insulation structure, online partial discharge monitoring, silent operation, and strong short‑circuit withstand capability. It meets IEC and GB standards, supports customization, and is widely used in urban power grids, industrial parks, new energy stations, unattended substations, plateau and mountain power distribution projects.

2. Product Advantages

Permanent Magnet Mechanism & Stability
- Adopts sealed permanent magnet operating mechanism
- No spring fatigue or mechanical wear; action accuracy ≤±1ms
- Mechanical life ≥30,000 operations
- Reduces power outage risk; suitable for unattended stations
High-Altitude Adaptation & Insulation
- Optimized epoxy resin integrated arc extinguishing chamber
- H‑class insulation; insulation strength increased by 20%
- Stable operation up to 1000m altitude
- Certified to GB/T 20635; no extra insulation needed
- Avoids altitude‑related insulation breakdown


Low-Noise Operation & Environmental Adaptation
- Silent closing design; operating noise ≤55dB
- Complies with IEC 60664
- Wide temperature range: -30℃ ~ +45℃
- Humidity resistance up to 95%RH
- Built‑in anti‑condensation heating device
Short-Circuit Withstand & Equipment Protection
- Rated breaking current up to 40kA
- Transverse magnetic field arc extinguishing
- Breaking time ≤50ms; no reburning
- Protects transformers, cables and back‑end equipment

3. Why choose us

why choose us Products?
✅ Factory Strength: 18 years export experience; 100,000 ㎡ workshop
✅ Patent & R&D: 56 national patents; professional R&D team
✅ Quality System: ISO & CE certified; full inspection
✅ Product Line: Transformers, switchgear, RMU, substations, breakers
✅ Custom Capacity: Mechanism, parameters, interface customizable
✅ Service: 12‑months warranty; one‑stop solution & on‑site support
one-stop solution
professional team
high quality
4. Product Specifications
| Number | Parameter name | Unit | Technical Parameters | |||
| 1 | Rated voltage | kV | 12 | |||
| 2 | Rated short-time frequency withstand voltage (1 min) | kV | 42 | |||
| 3 | Rated lightning impulse withstand voltage (peak) | kV | 75 | |||
| 4 | Rated frequency | Hz | 50 | |||
| 5 | Rated current | A | 630/1250/1600/2000/2500/3150/4000 | |||
| 6 | Rated short-circuit breaking current | kA | 20 | 25 | 31.5 | 40 |
| 7 | Rated short-time withstand current | kA | 20 | 25 | 31.5 | 40 |
| 8 | Rated short circuit duration | S | 4 | |||
| 9 | Rated short-circuit closing current | kA | 50 | 63 | 80 | 100 |
| 10 | Rated peak withstand current | kA | 50 | 63 | 80 | 100 |
| 11 | Number of rated short-circuit current starts | times | 30 | 30 | 30 | 20 |
| 12 | Rated individual capacitor bank opening current | A | ≤630 | |||
| 13 | Rated back-to-back capacitor bank opening current | A | ≤400 | |||
| 14 | Rated capacitor bank closing inrush current | kA | 12.5(frequency≤1000Hz) | |||
| 15 | Closing time | ms | ≤80 | |||
| 16 | Split time | ms | Maximum Voltage | ≤40 | ||
| ms | Rated Voltage | ≤50 | ||||
| ms | Minimum Voltage | ≤60 | ||||
| 17 | Time of ignition | ms | ≤15 | |||
| 18 | Mechanical life (M2) | times | 30000 | |||
| 19 | Allowable cumulative thickness of dynamic and static contact wear | mm | 3 | |||
| 20 | Rated closing operating voltage | V | AC/DC 220, AC/DC 110 | |||
| 21 | Rated breaking operating voltage | V | AC/DC 220, AC/DC 110 | |||
| 22 | Rated operating voltage of energy storage motor | V | AC/DC 220, AC/DC 110 | |||
| 23 | Rated power of energy storage motor | W | 80 (40KA Motor speed 100W) | |||
| 24 | Energy storage time | s | ≤15 | |||
| 25 | Contact opening distance | mm | 9±1 | |||
| 26 | Over traveling distance | mm | 3.5±0.5 | |||
| 27 | Contact closing bounce time | ms | ≤2 | |||
| 28 | Three-phase switching and closing non-synchronous | ms | ≤2 | |||
| 29 | Contact splitting rebound amplitude | mm | ≤3 | |||
| 30 | Contact closing contact pressure | kA | 20 | 25 | 31.5 | 40 |
| N±8% | 2200 | 2500 | 3100 | 4750 | ||
| 31 | Average breaking speed (contacts separated by 6mm) | m/s | 1.1±0.2 | |||
| 32 | Average closing speed (6mm contact closure) | m/s | 0.6±0.2 | |||
| 33 | Dominant electric circuit resistance | A | 630 | 1250 | 1600-2000 | ≥2500 |
| 34 | μΩ | ≤50 | ≤45 | ≤35 | ≤25 | |
| Rated operating sequence (1) 20~31.5KA | Minutes - 0.3s - combined minutes - 180s - combined minutes | |||||
| 35 | Rated sequence of operation (2) 40KA | Minutes - 0.3s - combined minutes - 180s - combined minutes | ||||
| Secondary circuit frequency withstand voltage (1min) | V | 2000 | ||||
Hot Tags: High Voltage Vacuum Circuit Breaker, China High Voltage Vacuum Circuit Breaker manufacturers, suppliers, factory, circuit breaker, Embedded Poles Type Vacuum Circuit Breaker, Fixed Type Vacuum Circuit Breaker, High Voltage Circuit Breaker, Indoor Solid Sealed Vacuum Circuit Breaker, Withdrawable Type Vacuum Circuit Breaker