1. Product Introduction
Kechang's core advantage is vacuum arc extinguishing technology. Its arc extinguishing chamber uses a high vacuum environment to extinguish the arc in less than 20 milliseconds when the current crosses zero, quickly cutting off short-circuit faults. The spiral contacts with transverse magnetic field design reduce ablation and extend service life, providing reliable grid protection.

2. Product Advantages

Maintenance-Free Design Cuts OPEX
Equipped with a fully sealed vacuum arc extinguishing chamber, the internal components of the equipment are completely isolated from the external environment. This means you won't need to perform regular cleaning or replace parts. The core spring operating mechanism has undergone strict testing, boasting a mechanical life of up to 30,000 times-no lubrication or maintenance is required at all. Compared with traditional equipment that needs inspection and maintenance at least twice a year, this one can cut on-site maintenance workload by 90%, effectively reducing OPEX. It's especially well-suited for projects where frequent maintenance is difficult to carry out.
Wide Temperature Range & High Protection
The equipment features an IP44 protection level, with a thickened anti-corrosion galvanized steel shell and a tight sealing structure. These designs effectively keep out dust, water vapor and corrosive gases. It can operate stably in a temperature range of -25℃ to 45℃, even at an altitude of 2000 meters and a relative humidity of 95%, without the need for additional protective devices. Its internal insulation components are made of Class H (180℃) materials, which can withstand high temperatures for a long time and are not easy to age-perfect for stable operation in both peak summer heat and cold winter conditions.


Low Noise & Flame Retardant Safety
For places like commercial buildings, hospitals and data centers, equipment noise and fire safety are crucial. We've optimized the equipment's operating mechanism and added shock absorption components, so the operating noise is controlled below 45dB, which meets IEC noise standards. Even if installed in a power distribution room near offices or residential areas, it won't cause any interference. The entire machine adopts an oil-free design, and its core insulation components are cast with F1-grade flame-retardant epoxy resin-this completely eliminates hidden dangers of oil leakage and fire. It has passed IEC 60076 fire certification, fully meeting the high safety requirements of densely populated areas.
3. Product Application

4. Operating Environment
- Ambient temperature
- Maximum temperature:+40℃ Minimum temperature:-15℃
- Daily average value is not more than +35℃ Altitude: not more than 1000m
- Daily average relative humidity:≤95% Monthly average relative humidity:≤90%
- Earthquake intensity: no more than 8 degrees
- And places without dripping water, steam, flammable gas, fire, explosion danger, chemical corrosion and severe vibration.
- The vacuum arc chamber adopts reliable metallization process and welding structure, which can operate with power for a long time.
5. Product Specifications
| Number | Parameter name | Unit | Technical Parameters | |||
| 1 | Rated voltage | kV | 12 | |||
| 2 | Rated short-time frequency withstand voltage (1 min) | kV | 42 | |||
| 3 | Rated lightning impulse withstand voltage (peak) | kV | 75 | |||
| 4 | Rated frequency | Hz | 50 | |||
| 5 | Rated current | A | 630/1250/1600/2000/2500/3150/4000 | |||
| 6 | Rated short-circuit breaking current | kA | 20 | 25 | 31.5 | 40 |
| 7 | Rated short-time withstand current | kA | 20 | 25 | 31.5 | 40 |
| 8 | Rated short circuit duration | S | 4 | |||
| 9 | Rated short-circuit closing current | kA | 50 | 63 | 80 | 100 |
| 10 | Rated peak withstand current | kA | 50 | 63 | 80 | 100 |
| 11 | Number of rated short-circuit current starts | times | 30 | 30 | 30 | 20 |
| 12 | Rated individual capacitor bank opening current | A | ≤630 | |||
| 13 | Rated back-to-back capacitor bank opening current | A | ≤400 | |||
| 14 | Rated capacitor bank closing inrush current | kA | 12.5(frequency≤1000Hz) | |||
| 15 | Closing time | ms | ≤80 | |||
| 16 | Split time | ms | Maximum Voltage | ≤40 | ||
| ms | Rated Voltage | ≤50 | ||||
| ms | Minimum Voltage | ≤60 | ||||
| 17 | Time of ignition | ms | ≤15 | |||
| 18 | Mechanical life (M2) | times | 30000 | |||
| 19 | Allowable cumulative thickness of dynamic and static contact wear | mm | 3 | |||
| 20 | Rated closing operating voltage | V | AC/DC 220, AC/DC 110 | |||
| 21 | Rated breaking operating voltage | V | AC/DC 220, AC/DC 110 | |||
| 22 | Rated operating voltage of energy storage motor | V | AC/DC 220, AC/DC 110 | |||
| 23 | Rated power of energy storage motor | W | 80 (40KA Motor speed 100W) | |||
| 24 | Energy storage time | s | ≤15 | |||
| 25 | Contact opening distance | mm | 9±1 | |||
| 26 | Over traveling distance | mm | 3.5±0.5 | |||
| 27 | Contact closing bounce time | ms | ≤2 | |||
| 28 | Three-phase switching and closing non-synchronous | ms | ≤2 | |||
| 29 | Contact splitting rebound amplitude | mm | ≤3 | |||
| 30 | Contact closing contact pressure | kA | 20 | 25 | 31.5 | 40 |
| N±8% | 2200 | 2500 | 3100 | 4750 | ||
| 31 | Average breaking speed (contacts separated by 6mm) | m/s | 1.1±0.2 | |||
| 32 | Average closing speed (6mm contact closure) | m/s | 0.6±0.2 | |||
| 33 | Dominant electric circuit resistance | A | 630 | 1250 | 1600-2000 | ≥2500 |
| 34 | μΩ | ≤50 | ≤45 | ≤35 | ≤25 | |
| Rated operating sequence (1) 20~31.5KA | Minutes - 0.3s - combined minutes - 180s - combined minutes | |||||
| 35 | Rated sequence of operation (2) 40KA | Minutes - 0.3s - combined minutes - 180s - combined minutes | ||||
| Secondary circuit frequency withstand voltage (1min) | V | 2000 | ||||
Hot Tags: Electrical Vacuum Breaker, China Electrical Vacuum Breaker manufacturers, suppliers, factory, outdoor circuit breaker, hv circuit breaker, dc circuit breaker, blown circuit breaker, standard circuit breaker, industrial circuit breaker