Automatic Ring Main Unit

Automatic Ring Main Unit

Details
Cost advantage
Fully sealed design
Modular design
Scalable Design
Category
Ring Main Unit
 
Send Inquiry
Description
Technical Parameters

Products Description

Automatic Ring Main Unit
 
 

What is Automatic Ring Main Unit?

The automatic ring network cabinet (RMU) is a medium-voltage power distribution switchgear that provides stable power supply for the ring network power distribution system. It integrates switching, protection, monitoring and remote control functions in a compact cabinet. Unlike traditional manual ring network cabinets, this automated cabinet can be equipped with intelligent controllers and communication modules to collect operating data in real time and quickly respond to power grid failures. When a certain section of the distribution network fails, the equipment automatically isolates the fault section to ensure the continuous power supply of the non-fault loop, effectively shortening the length of power failure and simplifying the operation and maintenance of power distribution.

 

Learn More>>

 

 

 
2006

Established

 
20+

years experience

 
200+

Employees

 
500+

Partners

Our advantages

Solid insulated ring main unit

01

Fully insulated and sealed structure

The core high-voltage components are designed with full insulation coating; the busbar and switch body are made of solid insulation materials to improve electrical safety and environmental adaptability. The cable connector is equipped with a fully insulated and fully shielded detachable connector, and the main circuit has a high level of protection, which can be dust-proof, moisture-proof, and anti-condensation under harsh working conditions.

02

Modular combination scheme

Functional units can be freely selected according to project requirements. Optional modules: load switch unit, load switch-fuse combination unit, circuit breaker unit, busbar segmentation unit, metering unit, voltage transformer PT unit. Flexible combination, to meet a variety of solutions such as incoming, outgoing, transformer protection, and electrical energy metering.

ring main unit switchgear

Compact Ring Main Unit

03

Airless insulation option

For scenarios that are not suitable for the use of gas-insulated equipment, the solid-insulated airless version can be selected. There is no need for daily inspection and operation and maintenance of SF6 gas to eliminate the hidden dangers of gas leakage. It is very suitable for urban distribution networks and indoor power distribution projects with high environmental protection requirements.

04

Reliable mechanical interlocking

The cabinet body is equipped with a mechanical interlocking between the main switch operation and the grounding operation to prevent misoperation and ensure the safety of operation and maintenance personnel in closing and overhauling operations. Clear location instructions and user-friendly panel layout are convenient for daily operation and inspection.

Modular Ring Main Unit

 

Compact Ring Main Unit
05
 

Intelligent monitoring and remote control

The automatic ring main unit can integrate intelligent control and communication systems to realize remote monitoring and operation. After the commissioning is completed, the equipment status, operating parameters and fault alarms can be viewed remotely, reducing the workload of on-site inspection and greatly improving the fault handling efficiency of a wide range of distribution networks.

Automatic ring main unit suitable for various power distribution projects

 

The automatic ring main unit is suitable for all kinds of power distribution projects. The selection needs to be combined with the system voltage, rated current, short-term tolerance parameters, protection scheme and installation environment to determine comprehensively. Tianjin Kechang International Trade supplies medium-voltage automatic ring network cabinets and complete sets of switchgear to overseas power distribution projects, supports customized configuration, provides drawings, test reports and technical services. Whether it is a municipal public network, an industrial plant, a commercial building or a new energy project, our engineers can match you with a suitable ring network cabinet solution.

 

Contact now

 

 

Project Unit XGNGZXD2-12C XGNGZXD2-12/F XGNGZXD2-12/V
Rated Voltage kV 12 12 12
Rated Frequency Hz 50 50 50
Rated Current A 630 Depend on Current Rating of the Fuse 630
Rated Insulation Level Rated Power-frequency Withstand Volatage (between Phases, to Earth) kV 42 42 42
Rated Power-frequency Withstand Voltage (Across the Isolating Distance) 48 48 48
Rated Power-frequency Withstand Voltage (Control and Auxiliary Circuit) 2 2 2
Rated Lightning Impulse (between Phases, to Earth) 75 75 75
Rated Lightning Impulse (Across the Isolating Diatance) 85 85 85
Rated Short-time Making Current kA 50 Limited by High Voltage Fuse 50
Rated Short-time Breaking Current kA - Limited by High Voltage Fuse 20
Mechar Vcal Life Load Switch/Circuit Breaker Times 10000 10000 10000
Disconnector/Earthing Switch 3000 3000 3000
Resistance of Main Circuit μΩ ≤120 - ≤120

Hot Tags: automatic ring main unit, China automatic ring main unit manufacturers, suppliers, factory, hv rmu, Environmentally Friendly Gas Insulated Ring Main Unit, 3 phase ring main, Outdoor Ring Main Unit, 13 8 kv ring main unit, 33kv ring main unit

Send Inquiry
Get Support for Your Power‑Distribution Projects

With our patented technologies, feel free to send your project-related inquiries via phone,
email or our online form. Our electrical-engineering specialists will reply to you promptly.

Submit Your Inquiry