Mv Vacuum Circuit Breakers

Mv Vacuum Circuit Breakers

Details
Rated Voltage:10KV 20KV 35KV
Rated Current:630A 1250A 2000A
Rated Short-Circuit Breaking Capacity:25kA 31.5kA 40kA
Insulation Level:LI75kV/AC35kV LI170kV/AC70kV LI325kV/AC145kV
Operation Mechanism:Spring-Operated
Protection Level:IP44 IP54
Frequency:50Hz 60Hz
Category
Circuit Breaker
Share to
Send Inquiry
Description
Technical Parameters

Solid Short-Circuit Resistance

 

When you're picking MV circuit breakers, handling short circuits without failure is a must-downtime here costs too much. Kechang's MV Vacuum Circuit Breakers are built with high-purity copper windings, and we use vacuum casting (VPI) tech for the coils to ensure winding uniformity. This boosts the unit's maximum short-circuit resistance significantly, so it can handle sudden current surges without damage. We also keep partial discharge (PD) levels ultra-low, which prevents internal component wear from electrical stress. No more unexpected failures during short circuits, no costly repairs or project delays-this breaker gives you the reliability you need for medium-voltage power networks.

 

Steady Cooling for Heavy Loads

 

Medium-voltage setups often run at high loads, and overheating is a common headache for procurement teams. Our MV Vacuum Circuit Breakers come with natural air cooling (AN) as standard-simple, energy-efficient, and perfect for regular load conditions. For sites with long-term heavy loads, you can add forced air cooling (AF) with durable, quiet fans. The breaker switches between AN and AF automatically based on internal temps, and we've added targeted ventilation slots to pull heat out faster. Even during peak load hours, temps stay in check-no thermal tripping, no reduced performance. Those AF fans only run when needed, so you save on energy without compromising on cooling.

 

Humidity-Resistant Insulation

 

MV breakers often go into damp or semi-outdoor areas, and insulation breakdown from moisture is a big risk. Kechang's MV Vacuum Circuit Breakers use a Class H (180°C) insulation system-stepping up from standard Class F to handle more heat and humidity. We wrap windings in Nomex paper and use flame-retardant epoxy resin for key components, so insulation stays strong even in high-humidity environments. This design keeps the breaker running reliably for 25-30 years, no frequent insulation checks or replacements. We'll provide full insulation test reports, so you can confirm it meets your project's environmental requirements without extra work.

 

Mv Vacuum Circuit Breakers

 

No-Fuss Installation & Maintenance

 

You don't have time for complicated installs or hard-to-maintain breakers-labor costs add up fast. Our MV Vacuum Circuit Breakers support both vertical and horizontal mounting, so they fit whatever layout your site has. We've kept the design compact, with lightweight housing that's easy to maneuver, even in tight spaces. Wiring is straightforward too-choose between copper busbars or cable terminals, and all access points are clearly laid out. Routine checks or part swaps take minutes, not hours, thanks to the open, user-friendly structure. This cuts down on installation labor time and long-term maintenance costs, keeping your project on budget.

 

Quiet Run for Nearby Spaces

 

If your MV breakers are installed near offices, residential areas, or hospitals, noise is a dealbreaker. We've fine-tuned these breakers for low noise: optimized iron core lamination to reduce magnetic hum, shock-absorbing pads on the housing, and low-noise fans for AF mode. Operating noise stays between 46-58 dB, right in line with IEC and GB standards. No more loud buzzing disrupting work or living spaces, no complaints from neighbors or staff. This breaker works just as well in urban substations as it does in industrial parks-quiet, but still tough enough for medium-voltage duty.

 

Tailored Fits & Full Compliance

 

Every medium-voltage project is different, and one-size-fits-all breakers always cause headaches. Kechang lets you tailor these MV Vacuum Circuit Breakers to your needs: adjust voltage levels, pick a capacity from 50kVA to 2000kVA, choose a protection grade up to IP44, or tweak fan layout and thermostat settings. No more modifying your site to fit the breaker-we build it to fit you. All units meet IEC 60076, IEEE C57, CE, UL, and RoHS standards, and comply with EU EcoDesign energy rules. We back them with a 3-year warranty, full certification docs, and on-site technical support. As an ISO 9001-certified maker, we ensure every breaker is consistent and reliable.

 

Product Specifications

 

Number Parameter name Unit Technical Parameters
1 Rated voltage kV 12
2 Rated short-time frequency withstand voltage (1 min) kV 42
3 Rated lightning impulse withstand voltage (peak) kV 75
4 Rated frequency Hz 50
5 Rated current A 630/1250/1600/2000/2500/3150/4000
6 Rated short-circuit breaking current kA 20 25 31.5 40
7 Rated short-time withstand current kA 20 25 31.5 40
8 Rated short circuit duration S 4
9 Rated short-circuit closing current kA 50 63 80 100
10 Rated peak withstand current kA 50 63 80 100
11 Number of rated short-circuit current starts times 30 30 30 20
12 Rated individual capacitor bank opening current A ≤630
13 Rated back-to-back capacitor bank opening current A ≤400
14 Rated capacitor bank closing inrush current kA 12.5(frequency≤1000Hz)
15 Closing time ms ≤80
16 Split time ms Maximum Voltage ≤40
ms Rated Voltage ≤50
ms Minimum Voltage ≤60
17 Time of ignition ms ≤15
18 Mechanical life (M2) times 30000
19 Allowable cumulative thickness of dynamic and static contact wear mm 3
20 Rated closing operating voltage V AC/DC 220, AC/DC 110
21 Rated breaking operating voltage V AC/DC 220, AC/DC 110
22 Rated operating voltage of energy storage motor V AC/DC 220, AC/DC 110
23 Rated power of energy storage motor W 80 (40KA Motor speed 100W)
24 Energy storage time s ≤15
25 Contact opening distance mm 9±1
26 Over traveling distance mm 3.5±0.5
27 Contact closing bounce time ms ≤2
28 Three-phase switching and closing non-synchronous ms ≤2
29 Contact splitting rebound amplitude mm ≤3
30 Contact closing contact pressure kA 20 25 31.5 40
N±8% 2200 2500 3100 4750
31 Average breaking speed (contacts separated by 6mm) m/s 1.1±0.2
32 Average closing speed (6mm contact closure) m/s 0.6±0.2
33 Dominant electric circuit resistance A 630 1250 1600-2000 ≥2500
34 μΩ ≤50 ≤45 ≤35 ≤25
Rated operating sequence (1) 20~31.5KA   Minutes - 0.3s - combined minutes - 180s - combined minutes
35 Rated sequence of operation (2) 40KA   Minutes - 0.3s - combined minutes - 180s - combined minutes
Secondary circuit frequency withstand voltage (1min) V 2000

Hot Tags: mv vacuum circuit breakers, China mv vacuum circuit breakers manufacturers, suppliers, factory, outdoor circuit breaker, hv circuit breaker, dc circuit breaker, blown circuit breaker, standard circuit breaker, industrial circuit breaker

Send Inquiry