Specifications: SCB10, 11, 12, 13
Rated voltage: 6kv, 10kv, 11kv, 33kv, 35kv
Rated capacity: 10KV-5000KVA load consumption
Category
Dry Type Transformers
Share to
Send Inquiry
Description
Technical Parameters

Product introduction

 

product-800-800
 
 

As the core power equipment of modern buildings and key distribution centers, dry transformers are widely used in high-rise buildings, commercial complexes, rail transit and data centers with strict fire protection requirements due to their high safety, environmental protection, flame retardant and maintenance-free characteristics.This product adopts advanced epoxy resin vacuum casting process, and the coil is formed at once in a high-precision mold to ensure excellent insulation performance and extremely low partial discharge.The products fully meet the latest energy efficiency standards of GB 20052, helping customers achieve safe, efficient and green power distribution goals.

Core advantages 

 

Excellent fire and flame retardant properties
 

The product uses epoxy resin as the main insulating material, which has the outstanding characteristics of non-flammable, self-extinguishing, and non-toxic smoke.Even at extreme high temperatures, it will not produce toxic gases or burst, completely eliminate fire hazards, and can be installed directly in the load center (such as the basement, inside the shopping mall), without the need for separate fireproof compartments and accident oil tanks, saving building space.

Dry Type Low Voltage Transformers

Vacuum pouring, strong crack resistance

 

1

Imported epoxy resin formula and vacuum pouring process are used to complete degassing, mixing and pouring in the mold to ensure that there are no air bubbles and no cavities inside the coil.After curing, a dense and hard whole is formed, with extremely high mechanical strength, strong short-circuit resistance, and can effectively prevent cracking caused by thermal expansion and contraction during operation, and adapt to frequent overload conditions.

Extremely low local discharge and loss
 

Thanks to strict manufacturing technology and high-quality insulation materials, the partial discharge of the product is controlled below 5pC (much lower than the national standard 10pC).At the same time, the iron core adopts high-permeability cold-rolled silicon steel sheet, combined with the stepped joint process, the no-load loss and load loss are much lower than the national standard value, and the economic benefits of long-term operation are significant.

gan

Intelligent temperature control and fan system

 

product-400-300

Standard intelligent temperature controller, real-time monitoring of three-phase winding temperature, with over-temperature alarm, tripping and automatic start and stop fan functions.In forced air cooling (AF) mode, the rated capacity of the transformer can be increased by about 40%, which can effectively cope with seasonal peak loads or emergency overload requirements and ensure the reliability of power supply.

Compact design and high protection level
 

Compact structure, small size and light weight.The standard product protection level is IP20, which can effectively prevent small animals or foreign objects from entering; optional IP23 protective cover, suitable for outdoor or humid, dusty industrial environments, without additional cabinets.

Compact Transformers
 

 

Main application scenarios

 

New energy power generation

Field use change and pooling change of photovoltaic power plants and wind power generation.

Commercial centers

Large shopping malls, supermarkets, hospitals, airports and other densely populated places.

Rail transit

Power lighting, ventilation and signal systems in subway and high-speed rail stations.

Industrial and data centers

Stable power supply for precision manufacturing, electronic factories, and server rooms.

 

 

 

 

 

 

Model Number Rated Volume Quantity
(KVA)
Voltage Combination(KV) Connecttion Group Label No-load Loss
(W)
Load Loss
(W)
No-load Electricity

(%)
Short Circuit Resistance

(%)
High Voltage High Voltage Tap Range Low Voltage
SCB12-M-30 30 6

6.3

10

10.5
±5%

or

±2×2.5%
0.4 Dyn11

or

Yyn0
150 710 2.0 4
SCB12-M-50 50 215 1000 2.0 4
SCB12-M-80 80 295 1380 1.5 4
SCB12-M-100 100 320 1570 1.5 4
SCB12-M-125 125 375 1850 1.3 4
SCB12-M-160 160 430 2130 1.3 4
SCB12-M-200 200 495 2530 1.1 4
SCB12-M-250 250 575 2760 1.1 4
SCB12-M-315 315 705 3470 1.0 4
SCB12-M-400 400 785 3990 1.0 4
SCB12-M-500 500 930 4880 1.0 4
SCB12-M-630 630 1070 5880 0.85 4
SCB12-M-630 630 1040 5960 0.85 6
SCB12-M-800 800 1215 6960 0.85 6
SCB12-M-1000 1000 1415 8130 0.85 6
SCB12-M-1250 1250 1670 9690 0.85 6
SCB12-M-1600 1600 1960 11730 0.85 6
SCB12-M-2000 2000 2440 14450 0.7 6
SCB12-M-2500 2500 2880 17170 0.7 6

Hot Tags: indoor flameproof epoxy resin cast dry-type transformer, China indoor flameproof epoxy resin cast dry-type transformer manufacturers, suppliers, factory, dry type auto transformer, Indoor Transformers, dry type isolation transformer, Distribution Dry Type Transformers, 30kva dry type transformer, ventilated dry type transformer