Electrical Distribution Transformers

Electrical Distribution Transformers

Details
Rated Voltage:HV 10kV 35kV;LV 400V 380V
Rated Capacity:500kVA 800kVA 1000kVA 1250kVA 1600kVA 2000kVA 2500kVA 3150kVA
Connection Vector Group:YNd11,Dyn11
Cooling Method:ONAN(Oil Natural Air Natural)/ONAF(Oil Natural Air Forced)
No-Load Loss:850W 1200W 1500W 1800W 2200W(corresponding to rated capacity)
Impedance Voltage:6% 8%(at rated capacity)
Frequency:50Hz 60Hz
Category
Power Transformers
Share to
Send Inquiry
Description
Technical Parameters

1. Product introduction

The Electrical Distribution Transformers we produce can be used normally in indoor and outdoor power distribution environments. They are currently mainly used in industrial production workshops, power grid systems, commercial buildings, infrastructure projects, and new energy power generation supporting occasions such as wind power and photovoltaic. The equipment relies on special mineral insulating oils for insulation and heat dissipation. The voltage conversion process is stable and reliable, the overall operating efficiency is high, and the short-term overload capacity is strong, which can meet the needs of long-term uninterrupted operation of the project.
Electrical distribution transformer cases

2. Product Features

High efficiency and low loss

In the design stage, the impedance, voltage regulation accuracy, and loss values will be reasonably matched to ensure the stable power supply quality and reduce unnecessary power consumption.

Low operating noise

By optimizing the iron core laminating process and the fixed structure of the box, the operating noise is controlled within the standard range, which meets the relevant requirements of IEC, and will not cause interference to the surrounding office and living environment.

Strong short circuit resistance

The winding can be made of copper or aluminum, and it can be used with vacuum dipping or vacuum drying treatment technology. The overall mechanical strength is high and the long-term operating performance is stable.

Factory inspection

Each electrical distribution transformers will complete a full set of electrical tests before leaving the factory to reduce the uncertainty of on-site installation and commissioning, and a complete test report can be provided.

Short-term overload capacity

The oil-immersed heat dissipation structure supports short-term overload operation and can cope with special working conditions such as peak electricity consumption.

 

Durability electrical distribution transformer

3. Choose our advantages

 

  • The electrical distribution transformers production plant has passed ISO certification, the production process is standardized, and the product quality is stable.
  • Focus on oil-immersed transformer design, mature and reliable oil circuit, cooling and insulation systems.
  • Support OEM/ODM customization, capacity, voltage, structure, and protection device can be adjusted.
  • Quality inspection of the whole process of production, including electrical testing, oil quality analysis and many other tests.
  • Provide export packaging and global logistics solutions, timely and efficient after-sales response.
Low noise electrical distribution transformer
 

4. FAQ

 

Everything You Need to Know
 

What cooling methods can be selected for transformers?

ONAN natural oil cooling is standard, and OFAF strong oil and strong wind cooling can be installed when the load is large and the temperature is high.

What are the insulation levels that can be achieved?

F-class and H-class insulation are commonly used, and they can be flexibly selected according to the project operating environment.

Can you customize capacity, voltage and structure?

Yes, the capacity, voltage, connection group, box size, radiator, and protection device all support personalized customization.

Do you provide test reports?

Yes, full electrical test, oil test and temperature rise test reports.

Products Description

 

5. Technical Specification

 

Model Number Rated Volume Quantity
(KVA)
Voltage Combination(KV) Connection Group Label No-load Loss
(W)
Load Loss
(W)
No-load Electricity
(%)
Short Circuit Resistance
(%)
High
Voltage
High Voltage Tap Range Low Voltage
S13-630 630 35 ±5%

or

±2×2.5%
3.15

6.3

10.5
yd11 580 7860 0.65 6.5
S13-800 800 690 9400 0.65 6.5
S13-1000 1000 810 11500 0.65 6.5
S13-1250 1250 980 13900 0.55 6.5
S13-1600 1600 1180 16600 0.45 6.5
S13-2000 2000 1520 18300 0.45 5.5
S13-2500 2500 1790 19600 0.45 6.5
S13-3150 3150 35

38.5
±5%
or
±2×2.5%
3.15
6.3
10.5
2130 23000 0.45 7
S13-4000 4000 2530 27300 0.45 7
S13-5000 5000 3020 31300 0.45 7
S13-6300 6300 3670 35000 0.45 8
S13-8000 8000 35

38.5
±5%

or

±2×2.5%
3.15
3.3
6.3
6.6
10.5
ynd11 5040 38400 0.35 8
S13-10000 10000 6090 45300 0.35 8
S13-12500 12500 7000 53800 0.30 8
S13-16000 16000 8470 65800 0.30 8
S13-20000 20000 10080 79500 0.30 8
S13-25000 25000 11900 94000 0.25 10
S13-31500 31500 14140 112000 0.25 10

 

Note: Under the condition that the tapping stages and voltage remain unchanged, iy is allowed to increase the negativetapping stages, reduce the positive tapping stages, or increase the positive tapping stages and reduce the negative tappingstages, such as 35X2.5%; 35+3X2.5%, etc. 

Hot Tags: electrical distribution transformers, China electrical distribution transformers manufacturers, suppliers, factory, 110kV Oil immersed Power Transformers, Electrical Distribution Transformers, Power Distribution Transformer, power transformers, Step Down Transformer, Three Phase 2 Winding OLTC Power Transformer