Three Phase 2 Winding OLTC Power Transformer

Three Phase 2 Winding OLTC Power Transformer

Details
Rated Voltage:HV 10kV 35kV 110kV;LV 6.3kV 10kV 400V
Rated Capacity:1000kVA 1250kVA 1600kVA 2000kVA 2500kVA 3150kVA 4000kVA
OLTC Tap Range:±8×1.25%/±10×1%
Connection Vector Group:YNd11,Dyn11
Cooling Method:ONAN(Oil Natural Air Natural)/ONAF(Oil Natural Air Forced)
Impedance Voltage:6% 8% 10.5%(at rated capacity)
Protection Level:IP44 IP54
Category
Power Transformers
Share to
Send Inquiry
Description
Technical Parameters

Product Introduction

Outdoor Transformers
  • Three Phase 2 Winding OLTC Power Transformer is an efficient power conversion equipment with integrated on-load voltage regulation function.
  • The product adopts an optimized combination design of dual-winding structure and on-load tap switch (OLTC), with high operating reliability and accurate voltage regulation accuracy.
  • The OLTC on-line monitoring unit equipped with it can collect the operating status data of the tap switch in real time, and cooperate with the insulation oil circulation filter to ensure the stable performance of the insulating oil, greatly reduce equipment operation and maintenance costs, and widely adapt to various medium and high voltage distribution engineering scenarios.

Product Features

  • Accurate on-load voltage regulation: equipped with a high-quality OLTC on-load tap switch, it can realize stepless voltage regulation under load, with a wide voltage regulation range and fast response speed, and can compensate for the voltage deviation of the power grid in real time to ensure that the output voltage is stable within the rated range to meet the power needs of precision equipment.

 

  • High-efficiency and energy-saving design: the use of low-loss oriented silicon steel sheet iron core and oxygen-free copper winding, treated by vacuum dip paint process, effectively reduces no-load loss and load loss, and the energy conversion efficiency reaches the first level of the national standard; at the same time, optimize the winding arrangement and core structure, reduce hysteresis loss and eddy current loss, long-term operation can significantly save power.
Three Phase 2 Winding OLTC Power Transformer advantage

Our Certification

 

1. ISO International Certification

We are ISO certified, and our entire process-from raw material selection to production and final inspection-adheres to international standards. This ensures the safety and durability of every transformer, helping customers reduce long-term maintenance costs and minimize potential safety risks.

 

2. CE Certification
Our transformers are CE certified and meet EU requirements. They can be directly exported to and used in all 27 EU member countries, reducing import and export costs and allowing customers to put the products into operation more quickly.

 

3. Type Test Report
Our transformers have successfully passed type tests conducted by authoritative institutions and are supported by complete test reports. They fully meet the requirements for smooth installation and acceptance in power grid and industrial projects.

Three Phase 2 Winding OLTC Power Transformer certification

FAQ

  • Q:How does an OLTC work?
  • A:An on-load tap changer (OLTC) automatically adjusts the transformer's taps to maintain a stable output voltage, preventing equipment damage caused by excessively high or low voltages.
  • Q:What industries are these transformers suitable for?
  • A:Three-Phase 2 Winding OLTC Power Transformers are widely used in power engineering, urban and rural power grid reconstruction, transportation, and communications.
  • Q: What is the service life of this transformer?
  • A: Three-phase, two-winding power transformers with OLTC can operate for over 30 to 50 years. Their long-term stability and durability are ensured by high-quality materials and strict manufacturing standards.
  • Q:What voltage levels are supported by our products?
  • A: Common rated voltages include 11kV, 33kV, 66kV, and 110kV. Customization is possible based on customer design requirements.
Low Losses Three Phase 2 Winding OLTC Power Transformer

Product Specifications

 

Model Number Rated Volume Quantity
(KVA)
Voltage Combination(KV) Connection Group Label No-load Loss
(W)
Load Loss
(W)
No-load Electricity
(%)
Short Circuit Resistance
(%)
High Voltage High Voltage Tap Range Low Voltage
S22-630 630 35 ±5%

or

±2×2.5%
3.15

6.3

10.5
yd11 470 5660 0.65 6.5
S22-800 800 560 6770 0.65 6.5
S22-1000 1000 660 8280 0.65 6.5
S22-1250 1250 790 10010 0.55 6.5
S22-1600 1600 950 11950 0.45 6.5
S22-2000 2000 1230 13180 0.45 6.5
S22-2500 2500 1450 14110 0.45 6.5
S22-3150 3150 35

38.5
±5%
or
±2×2.5%
3.15
6.3
10.5
1730 16560 0.45 7
S22-4000 4000 2050 19660 0.45 7
S22-5000 5000 2450 22540 0.45 7
S22-6300 6300 2970 25200 0.45 8
S22-8000 8000 35

38.5
±5%

or

±2×2.5%
3.15
3.3
6.3
6.6
10.5
ynd11 4090 27650 0.35 8
S22-10000 10000 4930 32620 0.35 8
S22-12500 12500 5670 38740 0.30 8
S22-16000 16000 6860 47380 0.30 8
S22-20000 20000 8160 57240 0.30 8
S22-25000 25000 9640 67680 0.25 10
S22-31500 31500 11460 80640 0.25 10

Hot Tags: three phase 2 winding oltc power transformer, China three phase 2 winding oltc power transformer manufacturers, suppliers, factory, 5kva continuous transformer, 3150 kva transformer, 112 kva transformer, Power Distribution Transformer, 220 volt ac to dc converter, 10kw transformer

Send Inquiry
Contact us if have any question

You can either contact us via phone, email or online form below. Our specialist will contact you back shortly.