Ring Network Switch Cabinet

Ring Network Switch Cabinet

Details
Rated Voltage:10KV 35KV
Rated Current:630A 1250A 2000A
Rated Short-Circuit Breaking Capacity:25kA 31.5kA 40kA
Insulation Level:LI75kV/AC35kV LI170kV/AC70kV
Protection Level:IP44 IP54
Frequency:50Hz 60Hz
Main Switch Type:Embedded Pole Vacuum Circuit Breaker
Category
Ring Main Unit
 
Send Inquiry
Description
Technical Parameters
Product introduction

Kechang ring main unit is designed for medium-voltage power distribution systems that require reliable power supply, flexible network configuration, and efficient equipment management.It is widely used in urban distribution networks, industrial facilities, commercial buildings, hospitals, data centers and infrastructure projects.
As an important part of the ring network power distribution system, the switchgear is connected to the inlet and outlet feeder circuits, so that power can be distributed through multiple network paths. When a certain part fails, the corresponding switching unit can isolate the affected circuit to maintain power supply to other parts of the network.

Compact Switchgear Unit

Competitive advantage

Flexible ring network configuration:

The switchgear supports different ring network configurations to meet the needs of medium voltage power distribution systems. According to the electrical single line diagram, multiple functional units can be used in combination to provide flexible solutions for incoming, outgoing and transformer protection. This configuration helps operators to manage power distribution more efficiently and isolate the fault segment when necessary.

01

Compact structure, optimized space:

The cabinet adopts a modular design, integrating the switch, protection and connection components in a compact housing. Compared with traditional power distribution equipment, its optimized layout helps reduce installation space requirements. The cabinet structure can be adapted to different equipment room sizes, cable entry directions and project layout. This makes it suitable for commercial basements, urban substations, and industrial facilities with limited space.

02

Reliable switching and protection:

According to the selected configuration, the switchgear can integrate load switches, vacuum circuit breakers and related protection devices. These components are designed to perform switching operations, manage feeder connections, and protect electrical equipment from abnormal operating conditions. The interlocking device helps prevent incorrect switching operation and improves operational safety. For power distribution systems that require continuous monitoring, optional monitoring components can also be integrated.

03

Adapt to different operating environments:

The Kechang ring main unit can be configured according to different installation environments and operating conditions. The shell protection, insulation arrangement and selection of internal components can be adjusted according to the project specifications. For the installation of coastal areas, humid environments or industrial sites, appropriate protective measures can be selected to improve the durability of the equipment. The design also considers daily operation, inspection and maintenance requirements, which helps to reduce unnecessary maintenance work during the service life of the equipment.

04

Project-based customization:

Different power distribution projects have different electrical requirements. Kechang can provide customized configurations according to rated voltage, rated current, short circuit tolerance, protection requirements and installation conditions. Optional configurations include 10kV and 35kV configurations, different combinations of functional units, protection relays, electrical interlocks, and remote monitoring systems. Technical drawings, equipment specifications and related test documents can be provided for project evaluation and approval.

05

SF6 ring main unit

 
 

Application area

Kechang ring network switchgear is suitable for various medium voltage power distribution applications:
-Urban power distribution: connect power distribution feeders to improve the flexibility of the power grid.
-Industrial park: power supply for production facilities, workshops and supporting infrastructure.
-Commercial buildings: provide medium voltage power distribution for shopping centers, office buildings, etc. Commercial complex.
-Hospitals and data centers: provide reliable power distribution support for facilities with demanding power needs.
-Renewable energy projects: in solar energy and other energy projects, access to medium-voltage power distribution systems is realized.

Why choose Kechang Electric?

 

Kechang Electric has more than 20 years of experience in the field of electrical equipment manufacturing, and is committed to providing medium voltage switchgear and integrated power distribution solutions for various international projects. Our production capacity covers precision metal processing, electrical assembly and comprehensive product testing. Each equipment must go through a strict inspection and testing process before leaving the factory. We provide customers with a full range of support, including technical consultation, customized drawing design, product technical documentation, installation guidance and after-sales service.

 

modular-1
One-stop Power Solutions in China

Welcome to contact Kechang Electric to discuss your ring network cabinet needs and obtain a configuration plan for your project.

Product Specifications

 

Project Unit Circuit Breaker Load Switch

Load Switch - Fuse

Combinations

Rated Voltage kV 12 12 12
Rated Frequency A 630/1250 630 125
Rated Current Hz 50 50 50
Rated Insulation Level 1 min Power Frequency Withstand Voltage (Interphase and Phase to Ground) kV 12 42 42
1 min Power Frequency Withstand Voltage (Isolating Distance) 48 48 48
Rated Power-frequency Withstand Voltage (Control and Auxiliary Circuit) 2 2 2
Rated Lightning Impulse (between Phases, to Earth) 75 75 75
Rated Lightning Impulse (Across the Isolating Diatance) 85 85 85
Rated Short-time Breaking Current kA 20/258 - 31.5
Rated Short-time Making Current kA 50/63 50 80
Rated Short-time Withstand Current kA 20/258 20 -
Rated Duration of Short-circuit s 4 4 -
Rated Peak Withstand Current kA 50/63 50 -
Take-over Current/ Transfer Current A - - 3150
Rated Operating Sequence - 0-0.3s-C0-180S-C0
Rated Filling Pressure (Gauge Pressure When Temperature is 20℃) Mpa 0.02
Minimum Functional Pressure (Gauge Pressure When Temperature is 20℃) Mpa 0
Pressure Relief Device Release Pressure (Gauge Pressure When Temperature is 20℃) Mpa 0.16
Yearly Gas Leakage Rate - ≤0.01%
Mechanical Life Times 10000
Main Loop Resistance μΩ ≤150

Hot Tags: ring network switch cabinet, China ring network switch cabinet manufacturers, suppliers, factory, hv rmu, Environmentally Friendly Gas Insulated Ring Main Unit, 3 phase ring main, Outdoor Ring Main Unit, 13 8 kv ring main unit, 33kv ring main unit

Send Inquiry
Get Support for Your Power‑Distribution Projects

With our patented technologies, feel free to send your project-related inquiries via phone,
email or our online form. Our electrical-engineering specialists will reply to you promptly.

Submit Your Inquiry