Resin Bonded Transformers

Resin Bonded Transformers

Details
Rated frequency 50 Hz/60 HZ
Three-phase
Energy saving effect is significant
Can operate in 100% wet environment without preheating treatment
Winding deformation rate <1.5% after bearing 25 times rated current shock
Category
Dry Type Transformers
 
Send Inquiry
Description
Technical Parameters

Ⅰ. Product Introduction

 

Resin-bonded transformers (Epoxy Resin Cast Transformer)use advanced epoxy resin vacuum-cast technology to solidify the windings into an overall structure. The equipment does not require any insulating oil and is an oil-free electrical equipment. Thanks to the fully encapsulated winding design, it has the characteristics of flame retardant, explosion-proof, pollution-free and maintenance-free.As an ideal power distribution equipment, it is particularly suitable for projects with extremely high safety and environmental protection standards, and is widely used in indoor power supply systems of various important public facilities and industrial sites.

Learn More

Insulated Transformers

II . Core strengths

cast resin transformer

-Excellent safety: it has flame-retardant and non-combustible characteristics, oxygen index ≥40%, conforms to building fire protection design specifications, and is suitable for densely populated public areas.
-Excellent environmental protection performance: there is no risk of oil leakage and no environmental pollution; the lowest operating noise can reach 52dB to meet the needs of noise-sensitive places. -Maintenance
-free structure: fully sealed design, protection level up to IP20/IP67, effective moisture-proof and dust-proof; continuous operation without preheating in a high humidity environment.
-High energy efficiency performance: The no-load loss of the SCB18 transformer is more than 40% lower than that of the SCB10 transformer, and the load loss is also 5%-8% lower than that of similar mainstream products, which significantly saves energy costs.
-Extremely strong mechanical strength: the short-circuit resistance is increased by 30%; when withstanding the impact of 25 times the rated current, the amount of winding deformation is controlled within 1.5%.
-Wide range of environmental adaptability: the operating temperature range covers -45℃ to +40℃; customized.

Learn More

III. Application scenarios

1. Commercial complex: Suitable for shopping mall renovation projects and other public spaces that have strict requirements for fire safety and noise control.
2. Data and financial infrastructure: Data centers and bank computer rooms have extremely high requirements for power supply reliability, and are designed to ensure the safe operation of core electronic equipment.
3. Hospitals and schools: Third-level hospitals and power distribution rooms on various campuses attach great importance to safety and environmental protection requirements.
4. Industrial field: The operating environment is harsh and the maintenance conditions are limited, which meets the power supply needs of "unattended" and "maintenance-free".

Single Phase Transformer

 

V. FAQ

Everything You Need to Know
 

Q1: What work is included in the demand analysis stage?

A: Confirm indoor/outdoor installation environment; calculate transformer rated capacity with ±15% allowance, and finalize overall technical parameters.

Q2: How to confirm core technical parameters for transformers?

A: Adopt common 10kV/0.4kV voltage ratio; prefer Dyn11 connection group for its excellent anti-harmonic performance.

Q3: How to audit qualified suppliers?

A: Inspect manufacturers' casting production equipment and process control; ask for practical operating projects of identical-spec products for reference.

Q4: What's the focus of economic comparison before purchase?

A: Compare power consumption & electricity costs among different efficiency grades; calculate long-term economic benefits brought by maintenance-free design.

 

6-10kV epoxy resin dry-type transformer (30-2500KVA)

Model Number Rated Volume Quantity
(KVA)
Voltage Combination(KV) Connecttion Group Label No-load Loss
(W)
Load Loss
(W)
No-load Electricity
(%)
Short Circuit Resistance
(%)
High Voltage High Voltage Tap Range Low Voltage
SC14-M-30 30 6

6.3

10

10.5
+3

-1

±5%

±2×2.5%

or

×2.5%
0.4 Dyn11

or

Yyn0
130 640 2.0 4
SC14-M-50 50 185 900 2.0 4
SC14-M-80 80 250 1240 1.5 4
SC14-M-100 100 270 1415 1.5 4
SC14-M-125 125 320 1665 1.3 4
SC14-M-160 160 365 1915 1.3 4
SC14-M-200 200 420 2275 1.1 4
SC14-M-250 250 490 2485 1.1 4
SC14-M-315 315 600 3125 1.0 4
SC14-M-400 400 665 3590 1.0 4
SC14-M-500 500 790 4390 1.0 4
SC14-M-630 630 910 5290 1.0 4
SC14-M-630 630 885 5365 0.85 6
SC14-M-800 800 1035 6265 0.85 6
SC14-M-1000 1000 1205 7315 0.85 6
SC14-M-1250 1250 1420 8720 0.85 6
SC14-M-1600 1600 1665 10555 0.85 6
SC14-M-2000 2000 2075 13005 0.7 6
SC14-M-2500 2500 2450 15445 0.7 6

Hot Tags: resin bonded transformers, China resin bonded transformers manufacturers, suppliers, factory, dry type auto transformer, Indoor Transformers, dry type isolation transformer, Distribution Dry Type Transformers, 30kva dry type transformer, ventilated dry type transformer

Send Inquiry
Get Support for Your Power‑Distribution Projects

With our patented technologies, feel free to send your project-related inquiries via phone,
email or our online form. Our electrical-engineering specialists will reply to you promptly.

Submit Your Inquiry